MHT Series

Features

  • Outlet Dewpoint with 100°F / 38°C Saturated Inlet
    • 38° F Pressure Dewpoint (PDP)
  • Available Input Voltages*
    • 115 VAC, 1 Phase, 60Hz
    • 208-230 VAC, 1 Phase, 60Hz
    • 230 VAC, 3 Phase, 60Hz
    • 460 VAC, 3 Phase, 60Hz
  • Maximum Pressure - 232 PSIG
  • Maximum Inlet Temperature - 200°F / 93°C

*NOTE: Voltage options are dependent on specific models.

Specifications

INLET Flow
(SCFM @ 100PSIG)
Inlet / Outlet Ports
(NPT)
Drain Port
(NPT)
Refrigerant Type Weight
(lbs)
Height
(in)
Width
(in)
Depth
(in)
MHT25 25 3/4" 1/4" R134a 95 21 18 17
MHT40 40 1" 165 26 20 26
MHT60 60 169
MHT75 75 205
MHT100 100 1-1/2" 210
MHT130 130 250 32 25 32
MHT150 150 2" R404a 310
MHT200 200 486 48 29 44

Sizing Dryers for Variable Conditions

Corrected Inlet Flow Capacity =

INLET Flow (above) x Inlet Pressure
Correction Factor
(A)
x Inlet Temp
Correction Factor
(B)
x Ambient Temp
Correction Factor
(C)
Inlet Pressure (PSIG) 100 125 150 175
Correction Factor (A) 0.85 0.90 1.00 1.10
Inlet Temp (°F) 100 125 150 180 200
Correction Factor (B) 1.25 1.10 1.05 1.00 0.79
Ambient Temp (°F) 80 90 100 110 120
Correction Factor (C) 1.16 1.03 1.00 0.90 0.85