HR Series

Features

  • Available Standard Outlet Dewpoints
  • Available Input Voltages
  • Maximum Pressure - 150 PSIG
  • Maximum Inlet Temperature - 120°F / 49°C

Specifications

HR1 HR2 HR3 HR4 HR5 HR6 HR6.5 HR7
INLET Flow
(SCFM @ 100 PSIG)
3.0 6.0 9.0 12.0 16.0 25.0 35.0 50.0
PURGE Flow
(SCFM @ 100 PSIG)
0.8 1.6 2.4 3.2 3.4 5.4 7.8 10.8
OUTLET Flow
(SCFM @ 100 PSIG)
2.2 4.4 6.6 8.8 12.6 19.6 27.2 39.2
Inlet / Outlet Ports
(NPT)
3/8" 1/2"
Weight
(lbs)
Height
(in)
Width
(in)
Depth
(in)
HR1 8.0 13.6 7.4 5.2
HR2 9.0 18.2
HR3 10.0 17.3
HR4 11.0 21.1
HR5 29.0 33.0 9.5 6.5
HR6 34.0 41.9
HR6.5 59.0 39.3 10.0 7.0
HR7 65.0 46.3

For INLET Pressures other than 100 PSIG

Maximum Inlet Flow (-40° F/C PDP) = INLET Flow (above) x INLET Flow Factor (A) @ Actual Pressure (below)

Maximum Inlet Flow (-100°F/-73°C PDP) = INLET Flow (above) x INLET Flow Factor (B) @ Actual Pressure (below)

Purge Flow = PURGE Flow (above) x PURGE Flow Factor (C) @ Actual Pressure (below)

Rated OUTLET Flow = Calculated Maximum Inlet Flow - Calculated Purge Flow

Actual Pressure (PSIG) 50 60 70 80 90 100 110 120 130 140 150
INLET Flow Factor (A) 0.32 0.43 0.55 0.69 0.84 1.00 1.09 1.18 1.26 1.35 1.44
INLET Flow Factor (B) 0.25 0.33 0.43 0.53 0.65 0.75 0.85 0.88 0.95 1.01 1.08
PURGE Flow Factor (C) 0.56 0.65 0.74 0.83 0.91 1.00 1.11 1.18 1.26 1.35 1.43