MDH1 | MDH2 | MDH3 | MDH4 | MDH5 | MDH6 | |
INLET Flow (SCFM @ 100 PSIG) |
0.40 | 0.80 | 1.10 | 1.60 | 2.40 | 3.20 |
PURGE Flow (SCFM @ 100 PSIG) |
0.10 | 0.20 | 0.27 | 0.40 | 0.60 | 0.80 |
OUTLET Flow (SCFM @ 100 PSIG) |
0.30 | 0.60 | 0.83 | 1.20 | 1.80 | 2.40 |
Inlet / Outlet Ports (NPT) |
1/8" | 1/4" |
Weight (lbs) |
Height (in) |
Width (in) |
Depth (in) |
|
MDH1 | 1.4 | 7.0 | 3.5 | 3.3 |
MDH2 | 1.5 | 10.3 | ||
MDH3 | 1.6 | 8.8 | 4.0 | 3.5 |
MDH4 | 1.9 | 10.1 | ||
MDH5 | 2.2 | 9.5 | 5.0 | 3.8 |
MDH6 | 3.1 | 11.5 |
For INLET Pressures other than 100 PSIG
Maximum Inlet Flow (-40° F/C PDP) = INLET Flow (above) x INLET Flow Factor (A) @ Actual Pressure (below)
Purge Flow = PURGE Flow (above) x PURGE Flow Factor (B) @ Actual Pressure (below)
Rated OUTLET Flow = Calculated Maximum Inlet Flow - Calculated Purge Flow
Actual Pressure (PSIG) | 50 | 60 | 70 | 80 | 90 | 100 | 110 | 120 |
INLET Flow Factor (A) | 0.32 | 0.43 | 0.56 | 0.70 | 0.85 | 1.00 | 1.09 | 1.17 |
PURGE Flow Factor (B) | 0.57 | 0.65 | 0.74 | 0.83 | 0.91 | 1.00 | 1.09 | 1.18 |
Puregas Australia is a division of Powerline Communications, who have been proudly providing communications engineering services for over thirty years. Initially entering the dry-air pressurisation market to support our utility customer’s requirements with their microwave communications networks, we became the distributors for Puregas dehydrators in Australia.
Phone: +61 7 3286 1888
Email: This email address is being protected from spambots. You need JavaScript enabled to view it.
2/6 Trade Street, Ormiston,
Queensland 4160, Australia