VCD Series - Mid-Range CO2 Adsorbers

Features

  • Outlet CO2 content to less than 1 PPM
  • Outlet H2O content to less than ( -100°F dew point)
  • Compact and lightweight design requires less space
  • Solid state timer with built-in memory for energy savings come standard
  • NEMA 1 Electrical
  • Purge mufflers and power cord come standard

Specifications

VCD3 VCD4
Outlet Flow Capacities (lpm) at Various Operating Pressures
50 PSIG* 5 16
60 PSIG* 9 26
70 PSIG* 13 33
80 PSIG* 15 37
90 PSIG 19 48
100 PSIG 23 60
110 PSIG 25 65
120 PSIG* 30 73
130 PSIG 33 85
140 PSIG 35 93
150 PSIG 38 99
* Factory selected purge orifice installed for these pressures - please state operating pressure with order
Flows (lpm) at 100 PSIG
Inlet Flow 40 95
Purge Flow 17 35
Outlet Flow 23 60
Additional Specifications
Inlet / Outlet Ports 1/4"
Power Requirements 115 VAC, Single Phase, 50/60 Hz or 220 VAC, Single Phase, 50/60 Hz
20 watts
Maximum Temperature 120°F ambient
Maximum Pressure 150 PSIG
Outlet CO2 Concentration Less that 1 PPM
Outlet H2O Concentration Less than 1 PPM (-100°F dew point)
Dimensions
Height 16.1" 24.1"
Width 8" 8"
Depth 4.8" 4.8"
Weight 9 lbs 14 lbs